Elcometer 138 (32 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
How does the Elcometer 138 measure coating thickness?
The Elcometer 138 uses magnetic induction and eddy current principles to determine coating thickness non-destructively. This provides fast, repeatable readings with minimal surface contact, which speeds quality checks. For best results, hold the probe steady, ensure full contact with the surface, and take several readings to verify consistency.
On which substrates can I use the Elcometer 138?
The instrument is suitable for both ferrous and non-ferrous substrates thanks to its dual measurement principles, allowing measurement on steel, aluminum and similar metals. This versatility reduces the need for multiple gauges. To ensure accuracy, select the correct mode for the substrate and verify with reference standards on the same material.
How accurate and repeatable are the measurements?
The Elcometer 138 is designed for high-precision measurements, delivering consistent and repeatable thickness values important for quality control. High repeatability helps detect coating defects and process variation. Improve repeatability by using a stable probe position, repeating measurements across the surface, and averaging results when required.
How do I calibrate the Elcometer 138 for best results?
Calibration is performed against known reference standards or calibration foils on the relevant substrate to eliminate systematic error and ensure traceability. Regular calibration preserves measurement validity and supports compliance. As a tip, calibrate after temperature changes and before critical tests, and document calibration checks to track instrument performance.
Can the Elcometer 138 measure on curved or textured surfaces?
Yes, the gauge can measure on moderately curved or textured surfaces, but surface geometry affects contact and accuracy, so readings may vary. Averaging multiple measurements reduces uncertainty and improves representativeness. For tight radii or coarse textures, use smaller contact areas, take more readings, and compare against flat reference plates where possible.
How does the device perform under different environmental conditions?
The Elcometer 138 is engineered to operate reliably in challenging environments, maintaining stable readings across typical shop and field conditions. Environmental robustness speeds inspections and reduces rework. To maximize accuracy, allow the instrument to thermally stabilize after large temperature shifts and avoid measurements in the presence of condensation or heavy contamination.
What maintenance is required to keep the Elcometer 138 reliable?
Routine maintenance includes keeping the probe face clean, avoiding drops or shocks, inspecting cables and connector integrity, and storing the unit in a protective case. Preventive care extends service life and maintains measurement accuracy. Replace damaged probe tips immediately and schedule periodic performance checks against certified standards.
What power source and battery life does the Elcometer 138 have?
The Elcometer 138 uses standard replaceable or rechargeable batteries designed for field use, offering multiple hours of operation depending on usage and display backlighting. Reliable battery performance minimizes downtime during inspections. To preserve battery life, switch off when idle, reduce display brightness if possible, and carry spare batteries for extended surveys.
Which accessories or probes are recommended for specific applications?
Recommended accessories include substrate-specific probe tips, calibration foils or plates, protective probe covers, and a rugged carry case to protect the instrument on site. Using the right probe and reference standards improves accuracy for thin or textured coatings. Choose accessories that match the substrate, coating thickness range, and inspection environment.
How can measurements from the Elcometer 138 demonstrate compliance with coating standards?
Measurements provide quantified coating thickness values that can be compared with industry specifications and acceptance criteria from common standards, supporting compliance and quality documentation. Documented measurement procedures and calibration records strengthen reports. For audits, record measurement locations, averages, tolerance assessments, and calibration evidence to substantiate conformity.
Related products from Elcometer
500
User manual 252 pages
415
User manual 112 pages
103
User manual 28 pages
456
User manual 28 pages
456
User manual 72 pages
456
User manual 72 pages
456
User manual 112 pages
456
User manual 112 pages
116C
User manual 33 pages
224
User manual 70 pages
2352
User manual 60 pages
2351
User manual 60 pages
2350
User manual 60 pages
2354
User manual 60 pages
2353
User manual 60 pages
550
User manual 80 pages
130
User manual 126 pages
MTG2
User manual 140 pages
MTG4
User manual 140 pages
MTG8
User manual 280 pages