SKF LAGM 1000E (116 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
How does the SKF LAGM 1000E measure grease quantity?
The SKF LAGM 1000E measures the amount of grease applied to a bearing or lubrication point. It can display the grease quantity in cm, gram, oz, or fl oz (US) depending on the selected unit.
What types of grease can the SKF LAGM 1000E handle?
The SKF LAGM 1000E is suitable for greases with a consistency ranging from NLGI 0 to NLGI 3. It is designed to work with various grease types and viscosities within this range.
What is the maximum pressure the SKF LAGM 1000E can handle?
The SKF LAGM 1000E can handle a maximum pressure of 70 MPa (10,000 psi), making it suitable for high-pressure grease applications.
How long does the battery last on the SKF LAGM 1000E?
The battery life of the SKF LAGM 1000E is up to 6 hours with the backlight on and 250 hours without the backlight. The device automatically turns off the battery after 1 minute of inactivity.
How do you reset the total counter on the SKF LAGM 1000E?
To reset the total counter, press the ZERO button while in the menu. This will reset the counter to zero, allowing you to track grease dispensed from the last reset.
How do you enter the calibration menu on the SKF LAGM 1000E?
To enter the calibration menu, press the and buttons simultaneously. This will display the current calibration factor and allow you to adjust it as needed.
How do you calculate the correction factor for the SKF LAGM 1000E?
The correction factor is calculated by dividing the real quantity of grease by the quantity shown on the meter. For example, if 500 grams are dispensed and the meter shows 485 grams, the correction factor is 500 / 485 = 1.03.
How do you calculate the new calibration factor for the SKF LAGM 1000E?
The new calibration factor is calculated by multiplying the old calibration factor by the correction factor. For instance, if the old calibration factor is 700 and the correction factor is 1.03, the new calibration factor is 700 x 1.03 = 721.
How do you change the calibration factor on the SKF LAGM 1000E?
To change the calibration factor, enter the calibration menu by pressing the and buttons simultaneously. Use the STEP button to adjust the highlighted digit and save the new value.
What is the operating temperature range for the SKF LAGM 1000E?
The SKF LAGM 1000E operates within a temperature range of -20 °C to +54 °C, with an IP67 rating for protection against dust and water ingress.
Related products from SKF
TKTL 21
User manual 116 pages
TKSA 40
User manual 432 pages
LAGD 1000
User manual 360 pages
TMRT 1
User manual 108 pages
TMEH 1
User manual 64 pages
TMEH 1
User manual 92 pages
TMSU 1
User manual 64 pages
TKRT 10
User manual 72 pages
TKRT 25M
User manual 80 pages
TMSP 1
User manual 84 pages
THGD 100
User manual 100 pages
TKRT 31
User manual 140 pages
TKRT 21
User manual 140 pages
TKBA 21
User manual 152 pages
TKBA 31
User manual 152 pages
TMVM 1
User manual 180 pages