Product description:
Frequently Asked Questions
How do I turn on the TMVM 1 viscometer?
To turn on the TMVM 1, press and hold the main switch for at least three seconds. The display will show the instrument designation for one second.
What is the measuring principle of the TMVM 1?
The TMVM 1 uses a rotor that rotates at a constant speed. The rotational resistance of the rotor, when immersed in the liquid, measures the viscosity of the liquid. This value is displayed on the digital screen.
What are the measuring ranges of the TMVM 1?
The TMVM 1 has three measuring ranges depending on the rotor used. The R3 rotor covers 30-1300 mPas, the R1 rotor covers 300-15,000 mPas, and the R2 rotor covers 10,000-400,000 mPas. These values are valid when using the measuring cup with the rotor.
What is the recommended way to use the TMVM 1 for accurate measurements?
For accurate results, fill the measuring cup with the substance to be tested. If not possible, use another vessel. Ensure the rotor is immersed up to the dip mark, and hold the viscometer horizontally using the holder or by hand. The point of orientation should rest on the forefinger for correct positioning.
What types of fluids is the TMVM 1 suitable for?
The TMVM 1 is suitable for fast tests and comparative viscosity measurements on lubrication oils. It is designed for Newtonian fluids, and the displayed values are only valid for these types of fluids when using the measuring cup.
What are the technical specifications of the TMVM 1?
The TMVM 1 is a rotational viscometer with a digital display. It uses a spiral spring system to measure viscosity based on the time offset between two pointers passing a light barrier. The device is compliant with the European Low Voltage Directive and EMC Directive.
What safety precautions should I follow when using the TMVM 1?
Always follow the operating instructions. Do not expose the TMVM 1 to rough handling, heavy impacts, or condensing humidity. Avoid using it in explosive environments. Do not modify the device or open the housing, as this voids the warranty.
What is the battery requirement for the TMVM 1?
The TMVM 1 requires four AA (LR6) alkaline batteries or rechargeable batteries with a capacity of more than 700 mA. The battery compartment is locked and can be opened using a screwdriver.
How do I interpret the displayed values on the TMVM 1?
The left-hand value on the display indicates the rotor used (R1 to R3), while the right-hand value shows the viscosity in mPas. The measurement is valid for Newtonian fluids and when using the measuring cup. Non-Newtonian fluids may yield different results.
What is the purpose of the orientation point on the TMVM 1?
The orientation point helps ensure the viscometer is held correctly during measurement. When using the device by hand, the orientation point should rest on the forefinger to maintain the correct horizontal position for accurate readings.
Related products from SKF
TKTL 21
User manual 116 pages
TKSA 40
User manual 432 pages
LAGD 1000
User manual 360 pages
TMRT 1
User manual 108 pages
TMEH 1
User manual 64 pages
TMEH 1
User manual 92 pages
TMSU 1
User manual 64 pages
TKRT 10
User manual 72 pages
LAGM 1000E
User manual 84 pages
LAGM 1000E
User manual 116 pages
LAGM 1000E
User manual 80 pages
TKRT 25M
User manual 80 pages
TMSP 1
User manual 84 pages
THGD 100
User manual 100 pages
TKRT 31
User manual 140 pages
TKRT 21
User manual 140 pages
TKBA 21
User manual 152 pages
TKBA 31
User manual 152 pages