Product description:
Frequently Asked Questions
What is the maximum hydraulic pressure of the pump?
The maximum hydraulic pressure of the SKF 728619 E pump is 150 MPa (21,750 psi). Exceeding this pressure can lead to equipment damage and safety risks.
What is the flow rate of the pump below and above the switching pressure?
Below the switching pressure of 2.5 MPa (362 psi), the pump delivers 20 cm³ per stroke. Above this pressure, the flow rate decreases to 1 cm³ per stroke.
What type of hydraulic oil should be used with the pump?
Use SKF LHMF 300 or LHDF 900 hydraulic oils, which have viscosities of 300 mm²/s and 900 mm²/s respectively at 20 °C. Avoid glycerin or water-based fluids as they can cause premature wear.
How should the pump be operated to ensure safety?
Always use trained personnel, wear protective gear, and ensure the equipment is fully inspected before use. Do not operate the pump above the maximum pressure, and never adjust safety valves beyond the maximum working pressure.
What is the purpose of the release valve?
The release valve allows the oil to flow back to the oil container after reaching the desired pressure. It is located on the side of the pump and should be opened carefully to prevent sudden pressure release.
How do you check the oil level in the pump?
Remove the container plug under the pump handle to check the oil level. Ensure there is enough oil to complete the operation, and use only clean hydraulic oils such as SKF LHMF 300 or LHDF 900.
What should be done if the oil system contains air?
Ensure there is no air in the oil system by operating the pump and checking that only air-free oil is supplied from the hose. Air in the system can cause malfunctions and reduce the pump's efficiency.
What are the dimensions of the pump?
The pump has dimensions of 170 mm (6.7 in) for A, 620 mm (24.4 in) for B, 130 mm (5.1 in) for C, and 128 mm (5.0 in) for D. These dimensions are important for proper installation and space planning.
What are the replacement parts for the pump?
Replacement parts include the pump itself (728619 E-1), a pressure gauge (728619 E-3), a double outlet adapter (728619 E-4), a repair kit (728619 E-7), a release valve assembly (728619 E-9), and various couplings and hoses.
What is the recommended maintenance for the pump?
Regularly inspect the pump for contamination and ensure the oil system is clean. Replace worn or damaged parts with genuine SKF components, and always follow proper procedures for filling, cleaning, and maintenance to ensure safe and efficient operation.
Related products from SKF
1077600/SET
User manual 41 pages
226400 E
User manual 56 pages
226400 E
User manual 160 pages
226400 E/400
User manual 56 pages
FlowMaster II
User manual 56 pages
226400
User manual 64 pages
729124
User manual 64 pages
729124
User manual 64 pages
729124
User manual 136 pages
TMJL 100
User manual 136 pages
TMJL 100
User manual 64 pages
TMJL 50
User manual 64 pages
TMJL 50
User manual 136 pages
THAP 030
User manual 102 pages
THAP 150
User manual 102 pages
CLU4
User manual 108 pages
CLU4
User manual 108 pages
SMD 3
User manual 115 pages
THAP 030E
User manual 164 pages
THAP 030E
User manual 397 pages