Dräger 5820 (100 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
How to turn on the device?
To turn on the device, press and hold the button for approximately 1 second until the start screen appears. An optional self-test will run, and after about 4 seconds, the display will show 'BEREIT' with a green LED blinking, indicating the device is ready for measurement.
How to calibrate the device?
The device is factory-calibrated. If the calibration date is more than 6 months old, it should be calibrated by Dräger Service. The calibration date can be optionally displayed after the start screen.
How to perform a breath test?
For each test subject, use a new mouthpiece. Blow steadily and continuously into the mouthpiece without interruption. A progress bar will appear, and a continuous tone indicates sufficient airflow. After 5 to 25 seconds, the measurement result with date and time will be displayed.
What to do if the device does not turn on?
If the device does not turn on, the battery may be depleted. Replace the battery. If the issue persists, contact Dräger Service for further assistance.
How to handle a low volume during a test?
If the volume is too small or the test is invalid, ensure the subject blows strongly and continuously into the mouthpiece without interruption. If the issue persists, repeat the test or contact Dräger Service.
How to change the mouthpiece?
To install the mouthpiece, insert it diagonally into the mouthpiece slot and press it in until it clicks into place. The textured marking on the mouthpiece will face upward. After installation, remove the packaging completely and proceed with the test.
How to perform a manual breath test?
If the subject cannot provide the required minimum volume, the sample can be manually triggered. After preparing the mouthpiece, press the button briefly when the progress bar appears. The display will show 'MANUELL' during the result.
How to perform a passive breath test?
For a passive test, press the button for about 1 second to display the start screen. Hold the device without the mouthpiece in the air to be analyzed. Press the button briefly to start the measurement. The display will show 'PASSIV' during the result.
How to turn off the device?
To turn off the device, press and hold the button for 3 seconds. The device will automatically turn off 4 minutes after the last operation.
How to access the menu settings?
To view the menu, press the button. Navigate through the menu using the or button. Confirm selected functions or inputs with the button. To exit the menu, select 'Back' in submenus or 'Measure' in the main menu.
Related products from Dräger
70
User manual 8 pages
DrugCheck 3000
User manual 26 pages
DrugCheck 3000
User manual 94 pages
Alcotest 4000
User manual 26 pages
Porta Control
User manual 28 pages
Aerotest 5000
User manual 44 pages
Aerotest 5000
User manual 88 pages
Aerotest Simultan HP
User manual 44 pages
Prestor 5000
User manual 48 pages
Flow Check
User manual 52 pages
Flow Check
User manual 64 pages
Alcotest
User manual 58 pages
RZ 7000
User manual 134 pages
Alcotest 5000
User manual 186 pages
Alcotest 5000
User manual 560 pages