Product description:
Frequently Asked Questions
How to measure airflow?
To measure airflow, set the selector switch to L/min. The display will show the airflow measurement.
How to generate negative pressure?
To generate negative pressure, set the selector switch to negative pressure mode and pump until the desired negative pressure is reached.
How to generate positive pressure?
To generate positive pressure, set the selector switch to positive pressure mode and pump until the desired positive pressure is reached.
How to perform a leak test?
To perform a leak test, set the selector switch to the leak test mode. Press the OK button to start the test.
How to quickly vent the system?
To quickly vent the system, set the selector switch to the vent mode. This will rapidly release any trapped pressure.
How to control the venting process?
To control the venting process, press the vent button until the pressure is reduced to the desired level. The vent button has two stages: the first stage provides slow venting, and the second stage provides a slower venting rate.
How to power the device?
The device can be powered using an internal battery, a power adapter, a USB cable connected to a PC, or a car charger. Only use the supplied accessories for power connections.
How to charge the battery?
Charge the battery only between 5°C and 40°C. Avoid direct sunlight. If the temperature is too high or too low, the device will automatically stop the charging process.
What are the technical specifications?
The device measures pressure from -30 mbar to +30 mbar with an accuracy of ±1% of the full scale. It measures airflow from 0.5 L/min to 4 L/min with an accuracy of ±5% of the measured value. The internal test volume is 500 mL.
What are the maintenance intervals?
Maintenance intervals include cleaning and disinfection every 6 years, inspection every 2 years, and a basic overhaul every 6 years. Ensure the device is stored in a dry place and protected from chemical exposure.
Related products from Dräger
70
User manual 8 pages
DrugCheck 3000
User manual 26 pages
Alcotest 4000
User manual 26 pages
Porta Control
User manual 28 pages
Aerotest 5000
User manual 44 pages
Aerotest 5000
User manual 88 pages
Aerotest Simultan HP
User manual 44 pages
Prestor 5000
User manual 48 pages
Flow Check
User manual 52 pages
Flow Check
User manual 64 pages
Alcotest
User manual 58 pages
5820
User manual 100 pages
Alcotest 5000
User manual 186 pages
Alcotest 5000
User manual 560 pages