Product description:

The Dräger Pac 3500 CO is a portable gas detection device designed for the measurement of carbon monoxide (CO) concentrations in the ambient air. It features a robust and compact design, ensuring ease of use in various industrial and environmental applications. The device provides accurate and reliable measurements through a highly sensitive electrochemical sensor. It includes an intuitive display for real-time data reading and offers alarm functions to alert users in case of hazardous CO levels. The Pac 3500 CO is suitable for use in confined spaces, occupational safety monitoring, and emergency response scenarios.

Frequently Asked Questions

How to turn the device on?

To turn the device on, press and hold the [OK] key. The display will count down until startup: '3, 2, 1'. All display segments will light up, followed by activation of the LED, alarm, and vibrating alarm. The device will perform a self-test, displaying the software version, gas name, remaining operation days, and alarm limits.

What happens during the initial activation of the device?

Upon first activation, the device will perform a self-test. The software version and gas name will be displayed. The remaining operation days will be shown, along with the A1 and A2 alarm limits. A fresh air calibration can be performed at startup by pressing [OK] during the flashing period of the gas value.

How to perform a bump test?

To perform a manual bump test, insert the Dräger Pac 3500/5500 into the calibration adapter or Bump-Test Station and connect a test gas cylinder with the appropriate gas ratios. Press [+] three times within three seconds to enter bump test mode. The device will beep twice, and the display will begin to flash. Open the regulator valve to allow test gas to flow over the sensor. If the gas concentration exceeds the alarm thresholds, the corresponding alarm will activate. Press [OK] to finish the bump test, or the device will automatically enter alarm mode if no alarm occurs within one minute.

What are the alarm thresholds for CO, H2S, and O2?

The alarm thresholds for CO, H2S, and O2 are as follows: CO - A1: 30 ppm, A2: 60 ppm; H2S - A1: 5 ppm, A2: 10 ppm; O2 - A1: 19 vol.-%, A2: 23 vol.-%. These thresholds can be adjusted according to country-specific regulations.

How to check the remaining life of the device?

To check the remaining life of the device, press [+] while the device is turned off. The remaining time in days will be displayed. Press [+] again to show 'd', and press [+] once more to display the gas being measured, such as 'CO'.

What is the purpose of the event logger?

The Dräger Pac 3500/5500 is equipped with an event logger that stores up to 60 events. If event No. 61 occurs, the logger overwrites the oldest stored event. Stored data can be downloaded to a PC using the connecting cradle or E-Cal System with the CC Vision Basic software.

How to adjust the operation timer?

The device is equipped with an adjustable operation timer that can be used to set an individual operation period, such as a 'calibration due date' or 'inspection due date'. To adjust the timer, connect the device to a PC using the connecting cradle or E-Cal System and use the CC Vision Basic software.

What are the alarm indications for A1 and A2?

During an A1 alarm, the LED will blink and the alarm will sound. During an A2 alarm, the LED and alarm tone will repeat in a double repeating pattern. The display will alternate between the measurement value and 'A1' or 'A2'. Alarms can be acknowledged or turned off based on the selected configuration.

What should be done if the bump test fails?

If the bump test fails and no alarm occurs within one minute, the device will enter alarm mode to indicate failure. The error icon [X] will flash, and error code 240 will be displayed. The measured value will be replaced with '– – –', and the [X] icon will remain visible. In this case, the bump test can be repeated or the device can be calibrated.

How to turn the device off?

To turn the device off, simultaneously hold both keys for approximately 2 seconds until '3' appears in the display. Continue holding both keys until the countdown finishes. A horn signal indicates that the device is turned off.