Log in


or


google Continue with Google

Already have an account?

Dräger X-am 2000 (116 pages)

0 out of 5
0 review

Tags

Loading...

Languages available:

No exact matches found. Please change your query

PDF page 1
Loading...
Need help?

Need help?

Do you have a question about the product that is not answered in the manual?

  • Receive updates on solutions
  • Get answers to your question

Ask a question

Select image (Optional)

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Product description:

The Dräger X-am 2000 is a multi-gas detector designed for the detection of various gases in industrial and occupational environments. It features a robust construction suitable for harsh conditions and offers reliable and accurate gas measurement. The device is equipped with multiple sensors for different gases and provides clear visual and audible alarms in case of gas exposure. It is easy to operate and can be configured for specific application requirements. The X-am 2000 is widely used in sectors such as petrochemical, mining, and process industries for safety monitoring and risk prevention.

Frequently Asked Questions

How to activate the device for the first time?

Before using the device for the first time, insert the included batteries or a charged NiMH power unit T4 (Order No. 83 18 704), see chapter 'Changing Batteries'. The Dräger X-am 2000 is ready for operation. For Dräger X-am 1100 and Dräger X-am 1700, perform the following activation sequence: press and hold the [ + ]-key for approximately 3 seconds until the countdown displayed on the screen '3 . 2 . 1' completes. The remaining operating time (not applicable for Dräger X-am 2000) will be shown, for example 'd 730' (remaining operating time 730 days). After this, the device automatically turns off and can be turned on at any time using the [OK]-key.

How to turn on the device?

To turn on the device, press and hold the [OK]-key for approximately 3 seconds until the countdown displayed on the screen '3 . 2 . 1' completes. During this time, all display segments, the optical, acoustic, and vibration alarms will be activated briefly. The software version will be displayed. The device performs a self-test. The remaining operating time will be shown, for example 'd 730' (remaining operating time 730 days). This applies to Dräger X-am 1100/1700 and when the usage duration is activated on Dräger X-am 2000. All alarm thresholds A1 and A2, as well as the TWA and STEL symbols for H2S and CO will be displayed sequentially. The time until the calibration interval expires will be shown in days, for example 'CAL 73'. During the sensor warm-up phase, the respective measurement value display and the warning symbol will blink. No alarm will be triggered during the sensor warm-up phase. Press the [OK]-key to cancel the startup sequence display.

How to turn off the device?

To turn off the device, press and hold the [OK]-key and [ + ]-key simultaneously until the countdown displayed on the screen '3 . 2 . 1' completes. Before turning off, the optical, acoustic, and vibration alarms will be activated briefly.

What is the operating range of the device?

The operating range for the gases is as follows: CO [ppm] 0 to 100, H2S [ppm] 0 to 25, and for other gases, the ranges vary. The standard gas configuration includes Ex, O2, CO, and H2S with specific ranges and units. The device measures concentrations of multiple gases in the ambient air at the workplace and in explosive areas.

How to perform a bump test?

A bump test (Bump Test Mode) must be performed according to national regulations before safety-critical measurements. It is necessary to check the calibration and adjust it if needed. The bump test ensures the device's functionality and accuracy under real conditions. The bump test mode can be activated through the quick menu using the [ + ]-key.

What are the alarm thresholds for A1 and A2?

The alarm thresholds for A1 and A2 are specified as follows: A1 has a threshold of 20 ppm for CO and 19 ppm for H2S, with quittable and non-self-maintaining properties. A2 has a threshold of 40 ppm for CO and 23 ppm for H2S, with non-quittable and self-maintaining properties. For O2, A1 is the lower alarm threshold and triggers an alarm when the concentration drops below it, while A2 is the upper alarm threshold and triggers an alarm when the concentration exceeds it.

How to interpret the alarm symbols on the display?

The alarm symbols on the display indicate different types of alerts. The symbol for a warning is shown as '⚠', while the symbol for a disturbance is shown as '⚠'. The symbol for peak value is shown as '📈', and the symbol for TWA (Time-Weighted Average) is shown as '📊'. The symbol for STEL (Short-Term Exposure Limit) is shown as '📉'. These symbols help users quickly identify the nature of the alarm and take appropriate action.

How to perform a fresh air calibration?

To perform a fresh air calibration, use the [OK]-key to select the function. Press the [ + ]-key to cancel the active function and return to the measurement mode. If no functions are activated in the quick menu, the device remains in measurement mode. Fresh air calibration ensures accurate readings by resetting the device to baseline conditions.

What happens during a battery low alarm?

During a battery low alarm, the warning symbol '⚠' blinks on the right side of the display. To acknowledge the alarm, press the [OK]-key, which disables the acoustic and vibration alarms. The battery will still last approximately 20 minutes after the first battery low alarm. If the main battery alarm occurs, the device will automatically shut off after 10 seconds. Before shutting off, the optical, acoustic, and vibration alarms will be activated briefly.

How to access the quick menu?

To access the quick menu during measurement mode, press the [ + ]-key three times. If functions for the quick menu have been activated using the PC software 'CC Vision', these functions can be selected using the [ + ]-key. If no functions are activated in the quick menu, the device remains in measurement mode. Possible functions include Bump Test Mode and Fresh Air Calibration.

Send answer

Additional user manuals for the same series

Your opinion matters to us

Do you think we can improve or add something? Are there features missing or do you have suggestions for improvement? We would love to hear from you.

Give a rating

5 out of 5
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.