Dräger X-am 5600 (280 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What is the purpose of the Dräger X-am 5600?
The Dräger X-am 5600 is a portable gas detection device used for continuous monitoring of multiple gas concentrations in ambient air at the workplace and in explosive areas.
What gases can the device measure?
The device can independently measure up to six gases depending on the installed DrägerSensoren.
What are the operating temperature ranges for the device?
The device is designed for use within a temperature range of -20 °C to +40 °C or +50 °C, and it is suitable for areas where gases of explosion class IIA, IIB, or IIC and temperature class T3 or T4 (depending on the battery and batteries) may be present.
Which power supply units are compatible with the device?
Only the power supply units ABT 0100 (83 22 237), HBT 0000 (83 18 704), or HBT 0100 (83 22 244) are compatible. Check the approved batteries and corresponding temperature classes on the power supply unit.
How do you perform the initial setup of the device?
To configure the device with a standard configuration individually, connect it via the USB-infrared cable (order number 83 17 409) or the E-Cal system to a PC. The configuration is performed using the PC software Dräger CC-Vision.
What is the default configuration of the device upon delivery?
The default configuration includes features such as bump test mode, fresh air calibration, hydrogen conversion, vital signs, shutdown, UEG factor, and averaging time, with specific settings like 4.4 Vol.-% for UEG and 15 minutes for STEL.
How do you turn on the device?
Press and hold the [ OK ]-button for approximately three seconds until the countdown displayed on the screen '3 . 2 . 1' completes. All display segments, optical, acoustic, and vibration alarms will be activated briefly, followed by a self-test and display of the next sensor to be calibrated.
What should you do before starting work with the device?
Before starting work, ensure the gas inlet opening is not blocked or dirty, check the calibration, and verify all alarm elements. Perform a bump test according to national regulations. Incorrect calibration can lead to false measurements and serious health damage.
How does the device indicate alarms?
The device indicates alarms optically, acoustically, and through vibration in the specified rhythm. For concentration pre-alarm A1, the display shows 'A1' and the measured value alternately, while for main alarm A2, it shows 'A2' and the measured value alternately.
What should you do when a main alarm occurs?
When a main alarm occurs, the corresponding displays, optical, acoustic, and vibration alarms are activated. The alarm is self-maintaining and cannot be acknowledged. After leaving the area and confirming the concentration has dropped below the alarm threshold, press the [ OK ]-button to disable the alarm messages.
Related products from Dräger
Pac 3500 CO
User manual 200 pages
Pac 5500 CO
User manual 200 pages
X-am 7000
User manual 56 pages
X-am 7000
User manual 64 pages
X-am 7000
User manual 88 pages
X-am 7000
User manual 120 pages
X-am 2500
User manual 248 pages
X-am 2500
User manual 328 pages
X-am 2500
User manual 352 pages
X-am 2500
User manual 400 pages
X-am 2500
User manual 420 pages
X-am 2000
User manual 116 pages
X-am 2000
User manual 116 pages
X-am 1700
User manual 116 pages
X-am 1700
User manual 116 pages
X-am 5000
User manual 117 pages
X-am 5000
User manual 204 pages
X-am 5000
User manual 212 pages
X-am 5000
User manual 264 pages
X-am 5000
User manual 328 pages