Product description:
Frequently Asked Questions
How to turn on the device?
To turn on the device, press and hold the [OK]-Taste for approximately 3 seconds until the countdown displayed on the screen '3 . 2 . 1' completes. During this time, all display segments, the optical, acoustic, and vibration alarms will be briefly activated. The software version will be shown, and the device will perform a self-test.
How to turn off the device?
To turn off the device, press and hold both the [OK]-Taste and [ + ]-Taste simultaneously until the countdown displayed on the screen '3 . 2 . 1' completes. Before shutting down, the optical, acoustic, and vibration alarms will be briefly activated.
What is the purpose of the Dräger X-am 5000?
The Dräger X-am 5000 is a portable gas meter for continuous monitoring of the concentration of multiple gases in ambient air at the workplace and in explosive areas. It can independently measure up to five gases according to the installed DrägerSensoren.
What are the operating temperature ranges for the device?
The device is designed for use within a temperature range of -20°C to +50°C. It is suitable for areas where gases of explosion classes IIA, IIB, or IIC and temperature classes T3 or T4 (depending on the battery and batteries) may be present.
How to check the calibration status before starting measurements?
Before conducting safety-relevant measurements, check the calibration and adjust it if necessary. A bump test (Bump Test) must be performed according to national regulations. Turn on the device, and the current measured values will be displayed on the screen. Pay attention to any warning or fault indication symbols.
What should be done if the CatEx sensor cannot be calibrated to the target concentration?
If the CatEx sensor cannot be calibrated to the target concentration, the sensor must be replaced. Exposure to catalytic poison gases in the measurement gas, such as volatile silicon, sulfur, heavy metal compounds, or halogenated hydrocarbons, can damage the CatEx sensor.
What happens when the device exceeds its measurement range?
When the device exceeds its measurement range, the following display appears instead of the measured value: » « (high concentration) or » « (negative drift). If there is a high concentration of combustible substances, it can lead to oxygen deficiency. If the oxygen concentration falls below 8 Vol.-%, a disturbance with » « is displayed in the Ex channel if the measured value is below the pre-alarm threshold.
What is the procedure for handling a main alarm (A2)?
A main alarm (A2) is self-maintaining and cannot be acknowledged. The device automatically turns off after 10 seconds. Before turning off, the optical, acoustic, and vibration alarms are briefly activated. Immediately leave the area, as there is a risk of life. After leaving the area and when the concentration falls below the alarm threshold, press the [OK]-Taste to disable the alarm messages.
How to access the Info-Mode during operation?
To access the Info-Mode during operation, press and hold the [OK]-Taste for approximately 3 seconds. If there are any warnings or disturbances, the corresponding warning or error codes will be displayed (see Technical Manual). Press the [OK]-Taste sequentially for the next display. Peak values and exposure values TWA and STEL will be shown. If no key is pressed for 10 seconds, the device will automatically return to the measurement mode.
What should be done if the device is not operational?
If the device is not operational, the display will show the special symbol » « on the right side. The device is not ready for operation. Contact maintenance personnel or the Dräger Service to resolve the issue.
Related products from Dräger
Pac 3500 CO
User manual 200 pages
Pac 5500 CO
User manual 200 pages
X-am 7000
User manual 56 pages
X-am 7000
User manual 64 pages
X-am 7000
User manual 88 pages
X-am 7000
User manual 120 pages
X-am 2500
User manual 248 pages
X-am 2500
User manual 328 pages
X-am 2500
User manual 352 pages
X-am 2500
User manual 400 pages
X-am 2500
User manual 420 pages
X-am 2000
User manual 116 pages
X-am 2000
User manual 116 pages
X-am 1700
User manual 116 pages
X-am 1700
User manual 116 pages
X-am 5600
User manual 236 pages
X-am 5600
User manual 280 pages
X-am 5600
User manual 284 pages
X-am 5600
User manual 304 pages
X-am 5600
User manual 396 pages