Product description:

The Elcometer MTG2 is a measuring instrument designed for precise thickness measurements of coatings and films. It utilizes advanced technology to ensure accurate and reliable results. The device is suitable for use in various industrial and laboratory environments where precise measurement of coating thickness is required. It features an intuitive interface and is built for durability and ease of use.

Frequently Asked Questions

How do I set the zero point on the gauge?

To set the zero point, connect the transducer, turn on the gauge, and navigate to Menu/Calibration/Zero Set. Apply couplant to the zero disk, press the transducer flat against the disk, and ensure the reading stability is 5 or more. Press 'Zero' to save the setting.

What are the measurement modes available on the MTG4?

The MTG4 has two measurement modes: Pulsed Echo (PE) and Echo-Echo ThruPaint™ (EE). Pulsed Echo measures from the transducer base to the material boundary, while Echo-Echo ThruPaint™ ignores up to 2.0mm of coating and measures from the material surface to the boundary.

How do I calibrate the MTG4 using the 1 Point method?

To use 1 Point calibration, connect the transducer, turn on the gauge, and navigate to Menu/Calibration/Cal Method. Select '1 Point' and follow the prompts to apply couplant to the sample, press the transducer, and adjust the reading to the known thickness value using the softkeys.

What is the purpose of the calibration method in the MTG4?

Calibration ensures accurate measurements by setting the correct sound-velocity for the material being tested. The MTG4 offers three calibration methods: 1 Point, Material, and Factory Calibration, each suited for different scenarios and materials.

How do I select the measurement units on the gauge?

To select the measurement units, press Menu/Setup/Units. You can choose between millimeters (mm) and inches (in), depending on your preference and the requirements of your measurement task.

What are the dimensions and weight of the gauge?

The gauge dimensions are 145 x 73 x 37mm (5.7 x 2.87 x 1.46") without the transducer, and it weighs 210g (7.4oz) including batteries but without the transducer.

What is the battery life indicator on the gauge?

The battery condition is indicated by a symbol in the top right of the display. A full symbol (orange) means the batteries are at full capacity, while an empty symbol (red, flashing) indicates the lowest sustainable level.

How do I connect a transducer to the gauge?

Align the red dot on the transducer plug with the red dot on the gauge base, then push the transducer into the gauge until the connector is fully engaged. Ensure the wearface is clean and free of debris before connecting.

What should I do before taking a measurement?

Before taking a measurement, ensure the gauge is powered on, the transducer is connected, the measurement mode is selected, the zero point is set, the gauge is calibrated, and the test surface is properly prepared.

What is the purpose of the screen settings menu?

The screen settings menu allows you to adjust the display brightness (Manual or Auto) and set the screen timeout period. You can also configure the gauge to automatically turn off after a period of inactivity to conserve battery life.