Frequently Asked Questions
What is the maximum insulation resistance the BM21 can measure?
The BM21 can measure insulation resistance up to 5 TΩ. It also has a mode to display leakage current, which allows for measuring even higher resistances, potentially up to 500 TΩ, though calibration is required for accurate readings.
How does the BM21 handle variable voltage testing?
The BM21 allows users to select a variable voltage between 25 V and 5000 V in 25 V increments. This feature enables continuous voltage adjustment during a test, though the measurement range (resistance, current, or burn mode) cannot be changed while operating on this range.
What should be done before starting an insulation test?
Before starting an insulation test, ensure the circuit under test is switched off, de-energized, and isolated. Avoid touching any circuit connections during the test, and make sure all test leads are in good condition with intact insulation.
How does the BM21 timer function during a test?
The BM21 timer can be set by the user to control the test duration, up to a maximum of 90 minutes. The timer starts automatically when the test button is pressed and stops when the set time is reached, unless the test is manually stopped or an error occurs.
What happens when the test is completed?
At the end of a test, the item under test is automatically discharged, and the decaying voltage is displayed until it drops below 50 V. The test leads should not be disconnected until the discharge is complete to avoid electric shock.
What is the battery life of the BM11D and BM21?
The BM11D and BM21 are powered by two rechargeable, sealed lead-acid batteries. These batteries typically last about 5 years under normal conditions. If not used for extended periods, the battery symbol will flash when the charge is critically low, and the instrument will shut off.
What is the purpose of the guard terminal on the instrument?
The guard terminal is used to connect the guard lead, which helps reduce the effect of leakage currents and improve measurement accuracy. It is particularly useful in high-impedance measurements and when testing capacitive loads.
How does the BM21 handle polarization index (PI) testing?
For polarization index (PI) testing, the BM21 can be set to a test duration of 10 minutes. This allows for measuring the ratio of insulation resistance at 1 minute and 10 minutes, which is useful for assessing the condition of insulation in cables and equipment.
What is the role of the battery symbol on the display?
The battery symbol on the display continuously shows the condition of the internal batteries. When fully charged, all segments of the symbol are lit. As the battery discharges, the segments dim, and the symbol flashes when the charge is critically low, indicating the need for recharging.
Related products from Megger
OTS80AF
User manual 12 pages
OTS60AF
User manual 12 pages
OTS 60PB
User manual 12 pages
OTS 60PB
User manual 56 pages
WM6
User manual 22 pages
SCITS100
User manual 35 pages
S1-5001
User manual 58 pages
DET5/4D
User manual 72 pages
DET5/4R
User manual 72 pages
DET10C
User manual 79 pages
DET20C
User manual 79 pages
BM25
User manual 88 pages
S1-5005
User manual 88 pages
BM80/2
User manual 89 pages
OTS 100AF/2
User manual 104 pages
OTS 80AF/2
User manual 104 pages
LCB2000/2
User manual 136 pages