Megger LCB2000/2 (136 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What is the maximum voltage rating for the instrument?
The instrument is designed for single and three phase systems rated up to 300V ac r.m.s. to earth. It complies with U.K., European, and other international wiring regulations.
Can the instrument store test results?
The LCB2500/2 model allows test results to be stored in internal memory for later recall, direct printing to a serial printer, or downloading to a PC for analysis and report generation.
What safety precautions should be taken when using the instrument?
Ensure continuity of protective conductors and earthed equipotential bonding before testing. Do not leave the instrument connected to the mains when not in use. Avoid touching live circuit connections and ensure test leads are in good condition.
How do I change the instrument settings?
To change settings, press and hold the Backlight key, turn the rotary selector switch to the RCD 150mA 40ms position, toggle the I key to select the desired setting, and press ENTER to save or EXIT to cancel.
What type of batteries are recommended for the instrument?
Use alkaline IEC LR6 (AA) or 1.5V nickel cadmium (NiCd) or nickel metal hydride (NiMH) cells only. Replace batteries immediately when the low battery symbol appears to ensure accurate testing.
What are the key features of the instrument?
The instrument offers loop impedance tests with resolution down to 0.01 ohm, RCD tests for selective, general, and DC-sensitive devices, automatic test start on voltage detection, and a large backlit LCD for clear display of results.
What is the purpose of the test leads?
Test leads are an integral part of the measuring circuit and must not be modified or used with other instruments. They are designed for use with the instrument and should not be altered in length or connected to unsuitable plugs.
How do I replace the batteries?
To replace batteries, disconnect the test leads, switch off the instrument, remove the battery compartment cover, and replace the cells ensuring correct polarity. Reconnect the battery holder and secure the cover properly.
What is the maximum current rating for the instrument's fuse?
The instrument is fuse protected to 440V 10kA. The maximum current that could flow through the fuse in the event of a fault is limited to 10kA by the impedance of the test leads.
What types of tests can the instrument perform?
The instrument can perform loop impedance tests, RCD tests, phase-phase, phase-neutral, and phase-earth tests. It also supports ramp tests, auto sequence tests, and measures supply voltage, frequency, and three-phase sequence.
Related products from Megger
OTS80AF
User manual 12 pages
OTS60AF
User manual 12 pages
OTS 60PB
User manual 12 pages
OTS 60PB
User manual 56 pages
WM6
User manual 22 pages
SCITS100
User manual 35 pages
S1-5001
User manual 58 pages
BM21
User manual 71 pages
DET5/4D
User manual 72 pages
DET5/4R
User manual 72 pages
DET10C
User manual 79 pages
DET20C
User manual 79 pages
BM25
User manual 88 pages
S1-5005
User manual 88 pages
BM80/2
User manual 89 pages
OTS 100AF/2
User manual 104 pages
OTS 80AF/2
User manual 104 pages