Product description:

The Elcometer 138 is a measuring instrument designed for precise measurement of coating thickness. It is commonly used in industrial and quality control applications to assess the thickness of paint, lacquer, and other protective coatings on various substrates. The device features a digital display for accurate readings and is suitable for both magnetic and non-magnetic materials. It is lightweight and easy to handle, making it ideal for on-site use. The Elcometer 138 ensures reliable and repeatable results, contributing to efficient quality assurance processes.

Frequently Asked Questions

How do I fit or replace the batteries?

To fit or replace the batteries, open the battery compartment and insert the lithium batteries according to the polarity markings. Ensure the batteries are correctly aligned and securely fitted. Close the compartment and check that the device powers on.

What are the controls and display indicators?

The conductivity meter has several controls and display indicators including a conductivity display, a calibration mode, a temperature compensation display, and various status indicators. The display shows the measured conductivity value, and the controls allow for calibration and unit selection.

How do I set the measurement units?

To set the measurement units, press the 'MEAS' button until the desired unit (e.g., µS/cm or mS/cm) is displayed. For calibration, use the 'CAL' button to enter calibration mode and adjust the reading according to the standard solution.

What is the procedure for one-point calibration?

For one-point calibration, ensure the meter is in the 'MEAS' mode, then press the 'CAL' button. Follow the on-screen prompts to input the known concentration of the calibration solution and adjust the meter accordingly to match the expected reading.

What is the purpose of the conductivity meter?

The conductivity meter is used to measure the conductivity of aqueous solutions. It is specifically designed for measuring salt content in coatings and surface treatments, and it is not suitable for measuring solids, organic solvents, or other non-aqueous substances.

What are the test procedures for ISO 8502-6 and ISO 8502-9?

The test procedures involve preparing the surface, calibrating the meter, and taking measurements according to the specified standards. The surface should be cleaned and dried before testing, and the meter should be calibrated using standard solutions. Measurements are taken at regular intervals to determine the surface density of salts.

What are the pass/fail criteria for the test?

The pass/fail criteria depend on the specific requirements of the test. Generally, the measured conductivity should fall within a specified range. If the reading exceeds the acceptable limits, the surface may be considered不合格 (non-compliant) based on the test standards.

What types of surfaces can be tested with this meter?

This meter is suitable for testing surfaces that are aqueous and conductive, such as coatings, paint, and other materials where salt content needs to be assessed. It is not designed for use with non-conductive or non-aqueous substances.

How do I calculate the surface density of salts?

To calculate the surface density of salts, use the formula provided in the manual. Measure the conductivity of the surface using the meter, and refer to the ISO salt mix table to determine the corresponding surface density. Subtract any baseline readings if required.

What is the recommended storage condition for the meter?

The meter should be stored in a cool, dry place away from direct sunlight and moisture. Ensure the battery compartment is closed when not in use to prevent damage to the internal components and prolong the life of the batteries.