Log in


or


google Continue with Google

Already have an account?

Dräger X-am 5000 (264 pages)

0 out of 5
0 review

Tags

Loading...

Languages available:

No exact matches found. Please change your query

PDF page 1
Loading...
Need help?

Need help?

Do you have a question about the product that is not answered in the manual?

  • Receive updates on solutions
  • Get answers to your question

Ask a question

Select image (Optional)

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Product description:

The Dräger X-am 5000 is a multi-gas detection device designed for use in industrial environments. It offers reliable and accurate measurement of various gases, including toxic and combustible gases. The device features a robust construction, ensuring durability in harsh conditions. It is equipped with a clear display and intuitive controls for easy operation. The X-am 5000 supports multiple gas detection ranges and can be configured for different application requirements. It is suitable for use in a wide range of industries, including chemical, petrochemical, and environmental monitoring.

Frequently Asked Questions

How often should the sensitivity be checked?

The sensitivity must be checked daily before the first use with a known concentration of the gas to be measured, corresponding to 25 to 50 percent of the concentration end value. The accuracy must be between 0 and +20 percent of the actual value. Accuracy can be corrected through calibration.

What is the purpose of the Dräger X-am® 5000?

The Dräger X-am® 5000 is a portable gas meter for continuous monitoring of the concentration of multiple gases in ambient air at the workplace and in explosive areas. It independently measures up to five gases according to the installed Dräger sensors.

What are the operating temperature ranges for the device?

The device is designed for use within a temperature range of -20 °C to +50 °C. It is suitable for areas where gases of explosion classes IIA, IIB, or IIC and temperature classes T3 or T4 (depending on the battery and batteries) may be present. For Zone 0, the temperature class is limited to T3.

What are the alarm configurations for the device?

Alarms A1 and A2 have configurable self-holding and acknowledgment features using the PC software Dräger CC-Vision. Alarm A1 is non-acknowledgable, self-holding, and triggers on rising edges, while Alarm A2 is non-acknowledgable, self-holding, and triggers on falling edges. Both alarms can be configured for different alert modes.

What are the functions of the display symbols?

The display symbols indicate various statuses such as disturbance alerts, warning alerts, peak value display, time-weighted average (TWA), short-term exposure limit (STEL), bump test mode, and fresh air calibration. These symbols help users quickly identify the current status of the device and its measurements.

How do you perform the initial setup of the device?

Before starting work, insert the included batteries or a charged NiMH power unit T4 (Type HBT 0000, Order No. 83 18 704) / T4 HC (Type HBT 0100, Order No. 83 22 244) (see chapter 'Changing Batteries' on page 9). The Dräger X-am 5000 is ready for operation once the batteries are installed.

What are the steps to turn on the device?

To turn on the device, press and hold the [OK] button for approximately three seconds until the countdown displayed on the screen » 3 . 2 . 1 « completes. During this time, all display segments, the optical, acoustic, and vibration alarms are briefly activated to check the proper function. The software version is displayed, followed by a self-test. The next sensor to be calibrated and the remaining days until the next calibration are shown, along with the time until the next bump test interval.

What are the alarm thresholds for toxic gases?

The alarm thresholds for toxic gases such as hydrogen sulfide (H2S) or carbon monoxide (CO) are set in the measurement units. These thresholds can be adjusted based on the sensor's capabilities and are displayed during the initial startup sequence. The thresholds are set between 0 and the measurement range end value.

What are the requirements for using the device in explosive areas?

The device is intended for use in explosive areas or mines where classified gases may be present. It is suitable for areas classified as Zone 0, 1, or 2, or Division 1 or 2, depending on the region. The device must be used only in areas where the risk of mechanical influence is low. It is designed for temperatures ranging from -20 °C to +50 °C and is suitable for gases or dust groups A, B, C, D, and temperature classes T3 or T4.

What should be done before performing safety-critical measurements?

Before performing safety-critical measurements, verify the calibration using a bump test (Bump Test), adjust if necessary, and check all alarm elements. If national regulations apply, the bump test must be conducted according to these regulations. Incorrect calibration can lead to false measurement results, which may result in serious health consequences.

Send answer

Your opinion matters to us

Do you think we can improve or add something? Are there features missing or do you have suggestions for improvement? We would love to hear from you.

Give a rating

5 out of 5
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.